FUEL INJECTION (FUEL SYSTEMS)(H4SO) > Tumble Generator Valve Assembly

REMOVAL

NOTE:

Tumble generator valve assembly is installed on EC, EK, K4, EH, ER and KA models.

1. Release the fuel pressure.

2. Disconnect the ground cable from the battery.

3. Open the fuel filler flap lid, and remove the fuel filler cap.

4. Remove the intake manifold.

5. Disconnect the connector from tumble generator valve actuator.

6. Remove the fuel injector.

7. Remove the tumble generator valve body from intake manifold.