DTC Troubleshooting: P1879 (32-1) (CVT)

DTC Troubleshooting: P1879 (32-1)

DTC P1879:  Problem in CVT Start Clutch Pressure Control Valve Circuit


NOTE: Record all freeze data before you troubleshoot.

1.Disconnect CVT start clutch pressure control valve connector.

2.Measure the resistance between connector terminals at the control valve connector.

 

SAA2E99K77100081321FAAD01CVT START CLUTCH PRESSURE
CONTROL VALVE CONNECTOR
Terminal side of male terminals

Is the resistance 3.8-6.8 W?


YES - Go to 3.


NO - Faulty the CVT start clutch pressure control valve, replace the control valve body.n


3.Disconnect the battery negative terminal.

4.Disconnect PCM connectors B (24P) and C (22P).

5.Check for continuity between PCM connector terminal B16 and body ground, and between terminal C8 and body ground.

 

SAA2E99K77100081321FAAD02Wire side of female terminalsPCM CONNECTORSC (22P)B (24P)SC LS+ (YEL)SC LS- (PNK/BLU)

Are there continuity?


YES - Repair short to ground in the wire between PCM connector terminal B16 and the CVT start clutch pressure control valve connector, and between terminal C8 and the CVT start clutch pressure control valve connector.n


NO - Go to 6.


6.Reconnect CVT start clutch pressure control valve connector.

7.Measure the resistance between PCM connector terminals B16 and C8.

 

SAA2E99K77100081321FAAD03Wire side of female terminalsPCM CONNECTORSC (22P)B (24P)SC LS+ (YEL)SC LS- (PNK/BLU)

Is the resistance 3.8-6.8 W?


YES - Check for loose terminal fit in the PCM connectors. If necessary, substitute a known-good  PCM and recheck.n


NO - Repair loose terminal or open in the wires between PCM connector terminals B16 and C8, and the CVT start clutch pressure control valve connector.n