Heater Control Panel Disassembly and Reassembly
NOTE: LHD type is shown, RHD type is symmetrical.
| 1. | Remove the heater fan switch (A), the air mix control cable (B), the mode control cable (C), and the recirculation control cable (D).
ACDB |
| 2. | Widen the cable stops (A) in the cable holder (B) using a snap ring pliers, then pull out the control cable (C).
CBA |
| 3. | Hook the tip of the new control cable to the lever or slider, then push the cable housing into the cable holder until it locks into place.
|
| 4. | After assembly, check that the lever slides or the dial turns smoothly through the full stroke from right to left.
|