Honda Jazz/Fit 2005 · Service Manual

Recirculation Control Motor Circuit Troubleshooting

Recirculation Control Motor Circuit Troubleshooting

1.Check the No. 10 (7.5A) fuse in the under-dash fuse/relay box.

Is the fuse OK?


YES - Go to 2.


NO - Replace the fuse, and recheck.n


2.Disconnect the recirculation control motor 7P connector.

3.Turn the ignition switch ON (II).

4.Measure the voltage between the No. 1 terminal of the recirculation control motor 7P connector and body ground.

 

SAA5ES0G24100050602FAAD01RECIRCULATION CONTROL MOTOR
7P CONNECTOR
Wire side of female terminalsBLK/YEL

Is there battery voltage?


YES - Go to 5.


NO - Repair open in the wire between the No. 10 fuse in the under-dash fuse/relay box and the recirculation control motor.n

5.Turn the ignition switch OFF.

6.Test the recirculation control motor.

Is the recirculation control motor OK?


YES - Go to 7.


NO - Replace the recirculation control motor, or repair the recirculation control linkage or doors.n


7.Disconnect climate control unit 28P connector.

8.Check for continuity between the No. 11 and No. 12 terminals of climate control unit 28P connector and body ground individually.

 

SAA5ES0G24100050602FAAD02CLIMATE CONTROL UNIT 28P CONNECTORWire side of female terminalsLT GRN/REDGRN/WHT

Is there continuity?


YES - Repair any short to body ground in the wire(s) between the climate control unit and the recirculation control motor.n


NO - Go to 9.

9.Turn the ignition switch ON (II), and check the same wires for voltage.

 

SAA5ES0G24100050602FAAD03CLIMATE CONTROL UNIT 28P CONNECTORWire side of female terminalsLT GRN/REDGRN/WHT

Is there any voltage?


YES - Repair any short to power in the wire(s) between the climate control unit and the recirculation control motor. This short may also damage the climate control unit. Repair the short to power before replacing the  climate control unit.n


NO - Go to 10.


10.Turn the ignition switch OFF.

11.Check for continuity between the following terminals of climate control unit 28P connector and the recirculation control motor 7P connector.

28P: 7P: 
No. 11 No. 7 
No. 12 No. 5 

 

SAA5ES0G24100050602FAAD04Wire side of female terminalsRECIRCULATION CONTROL MOTOR 7P CONNECTORWire side of female terminalsCLIMATE CONTROL UNIT 28P CONNECTORLT GRN/REDGRN/WHTGRN/WHTLT GRN/RED

Is there continuity?


YES - Check for loose wires or poor connections at climate control unit 28P connector and at the recirculation control motor 7P connector. If the connections are good, substitute a known-good climate control unit, and recheck. If the symptom/indication goes away, replace the original  climate control unit.n


NO - Repair any open in the wire(s) between the climate control unit and the recirculation control motor.n