A/C Condenser Fan Circuit Troubleshooting

A/C Condenser Fan Circuit Troubleshooting

1.Check the No. 1 (20A) fuse in the under-hood fuse/relay box, and the No. 14 (10A) fuse in the under-dash fuse/relay box.

Are the fuses OK?


YES - Go to 2.


NO - Replace the fuse(s), and recheck.n


2.Remove the condenser fan relay from the under-hood fuse/relay box, and test it.

Is the relay OK?


YES - Go to 3.


NO - Replace the condenser fan relay.n


3.Measure the voltage between the No. 2 terminal of the condenser fan relay 4P socket and body ground.

 

S5A1A08G10110212032FAAD01CONDENSER FAN RELAY 4P SOCKET

Is there battery voltage?


YES - Go to 4.


NO - Replace the under-hood fuse/relay box.n

4.Connect the No. 1 and No. 2 terminals of the condenser fan relay 4P socket with a jumper wire.

 

S5A1A08G10110212032FAAD02CONDENSER FAN RELAY 4P SOCKETBLU/YELJUMPER WIRE

Does the condenser fan run?


YES - Go to 5.


NO - Go to 8.


5.Disconnect the jumper wire.

6.Turn the ignition switch ON (II).

7.Measure the voltage between the No. 3 terminal of the condenser fan relay 4P socket and body ground.

 

S80WA86G10110212032FAAD03CONDENSER FAN RELAY 4P SOCKETBLK/YEL

Is there battery voltage?


YES - Replace the under-hood fuse/relay box.n


NO - Repair open in the wire between the No. 14 fuse in the under-dash fuse/relay box and the  condenser fan relay.n


8.Disconnect the jumper wire.

9.Disconnect the condenser fan 2P connector.

10.Check for continuity between the No. 1 terminal of the condenser fan relay 4P socket and the No. 2 terminal of the condenser fan 2P connector.

 

S5A1A08G10110212032FAAD03CONDENSER FAN RELAY 4P SOCKETBLU/YELWire side of female terminalsCONDENSER FAN 2P CONNECTORBLU/YEL

Is there continuity?


YES - Go to 11.


NO - Repair open in the wire between the  condenser fan relay and the condenser fan.n


11.Check for continuity between the No. 1 terminal of the condenser fan 2P connector and body ground.

 

S2AYA08G10110212032FAAD01CONDENSER FAN 2P CONNECTORBLKWire side of female terminals

Is there continuity?


YES - Replace the condenser fan motor.n


NO - Check for an open in the wire between the condenser fan and body ground. If the wire is OK, check for poor ground at  G201 (D17A2 engine model) or  G301 (K20A1 engine model).n