Honda STREAM 2001 · Service Manual

Recirculation Control Motor Circuit Troubleshooting - With Climate Control

Recirculation Control Motor Circuit Troubleshooting - With Climate Control

1.Check the No. 14 (10A) fuse in the under-dash fuse/relay box.

Is the fuse OK?


YES - Go to 2.


NO - Replace the fuse, and recheck.n


2.Disconnect the recirculation control motor 7P connector.

3.Turn the ignition switch ON (II).

4.Measure the voltage between the No. 1 terminal of the recirculation control motor 7P connector and body ground.

 

S5A1E4AG24100050602FAAD01RECIRCULATION CONTROL MOTOR
7P CONNECTOR
Wire side of female terminalsBLK/YEL

Is there battery voltage?


YES - Go to 5.


NO - Repair open in the wire between the No. 14 fuse in the under-dash fuse/relay box and the recirculation control motor .n


5.Turn the ignition switch OFF.

6.Test the recirculation control motor.

Is the recirculation control motor OK?


YES - Go to 7.


NO - Go to 12.


7.Disconnect climate control unit connector B (20P).

8.Check for continuity between the No. 18 and No. 19 terminals of climate control unit connector B (20P) and body ground individually.

 

S7A1E00G24100050602FAAD01GRN/WHTGRN/YELWire side of female terminalsCLIMATE CONTROL UNIT CONNECTOR B (20P)

Is there continuity?


YES - Repair any short to body ground in the wire(s) between the  climate control unit and the recirculation control motor.n


NO - Go to 9.


9.Turn the ignition switch ON (II), and check the same wires for voltage.

 

S7A1E00G24100050602FAAD02GRN/WHTGRN/YELWire side of female terminalsCLIMATE CONTROL UNIT CONNECTOR B (20P)

Is there any voltage?


YES - Repair any short to power in the wire(s) between the climate control unit and the recirculation control motor. This short also damages the  climate control unit. Repair the short to power before replacing the  climate control unit.n


NO - Go to 10.

10.Turn the ignition switch OFF.

11.Check for continuity between the following terminals of climate control unit connector B (20P) and the recirculation control motor 7P connector.

20P: 7P: 
No. 18 No. 5 
No. 19 No. 7 


 

S7A1E00G24100050602FAAD03Wire side of female terminalsWire side of female terminalsRECIRCULATION CONTROL MOTOR 7P CONNECTORGRN/WHTGRN/YELGRN/YELGRN/WHTCLIMATE CONTROL UNIT CONNECTOR B (20P)

Is there continuity?


YES - Check for loose wires or poor connections at climate control unit connector B (20P) and at recirculation control motor 7P connector. If the connections are good, substitute a known-good  climate control unit, and recheck. If the symptom/indication goes away, replace the original  climate control unit.n


NO - Repair any open in the wire(s) between the climate control unit and the recirculation control motor.n

12.Remove the recirculation contol motor.

13.Check the recirculation control linkage and doors for smooth movement.

Do the recirculation control linkage and doors move smoothly?


YES - Replace the recirculation control motor.n