Door Lock Actuator Test
Door Lock Actuator Test
Driver's Door without Super Locking:
| 1. | Remove the driver's door panel. |
| 2. | Disconnect the 2P connector (A) from the actuator.
|
| 3. | Check actuator operation by connecting power and ground according to the table. To prevent damage to the actuator, apply battery voltage only momentarily.
|
Driver's Door with Super Locking:
| 1. | Remove the driver's door panel. |
| 2. | Disconnect the 6P connector (A) from the actuator.
male termianls |
| 3. | Check actuator operation by connecting power and ground according to the table. To prevent damage to the actuator, apply battery voltage only momentarily.
|
Passenger's Door without Super Locking:
| 1. | Remove the passenger's door panel. |
| 2. | Disconnect the 2P connector (A) from the actuator.
|
| 3. | Check actuator operation by connecting power and ground according to the table. To prevent damage to the actuator, apply battery voltage only momentarily.
|
Passenger's Door with Super Locking:
| 1. | Remove the passenger's door panel. |
| 2. | Disconnect the 6P connector (A) from the actuator.
|
| 3. | Check actuator operation by connecting power and ground according to the table. To prevent damage to the actuator, apply battery voltage only momentarily.
|