DTC Troubleshooting: 6

DTC Troubleshooting: 6

DTC 6:  A Short in the Sunlight Sensor Circuit


1.Disconnect the sunlight sensor 2P connector.

2.Disconnect climate control unit connector B (20P).

3.Check for continuity between the No. 8 terminal of climate control unit connector B (20P) and body ground.

 

S7A1E00K71100081060FAAD01Wire side of female terminalsCLIMATE CONTROL UNIT CONNECTOR B (20P)ORN

Is there continuity?


YES - Repair short to body ground in the wire between the  climate control unit and the  sunlight sensor.n


NO - Go to 4.


4.Reconnect the sunlight sensor 2P connector.

5.Reconnect climate control unit connector B (20P).

6.Test the sunlight sensor.

Is the sunlight sensor OK?


YES - Substitute a known-good  climate control unit, and recheck. If the symptom/indication goes away, replace the original  climate control unit.n


NO - Replace the  sunlight sensor.n