Honda STREAM 2001 · Service Manual

DTC Troubleshooting: 10

DTC Troubleshooting: 10

DTC 10:  An Open or Short in the Mode Control Motor Circuit


1.Disconnect the mode control motor 7P connector.

2.Disconnect heater control panel connectors A (12P) and B (20P).

3.Check for continuity between body ground and heater control panel connector A (12P) terminals No. 3, and between body ground and heater control panel connector B (20P) terminals No. 2, 3, 5, 6, 13 and 15 individually.

 

S7A1E00K73100081100FAAD01Wire side of female terminalsHEATER CONTROL PANEL CONNECTOR A (12P)LT GRN

 

S7A1E00K73100081100FAAD02Wire side of female terminalsHEATER CONTROL PANEL CONNECTOR B (20P)YEL/GRNWHT/BLURED/YELRED/BLUYEL/BLUYEL/RED

Is there continuity?


YES - Repair any short to body ground in the wire(s) between the heater control panel and the mode control motor.n


NO - Go to 4.

4.Turn the ignition switch ON (II), and check the same terminals for voltage.

 

S7A1E00K73100081100FAAD03Wire side of female terminalsHEATER CONTROL PANEL CONNECTOR A (12P)LT GRN

 

S7A1E00K73100081100FAAD04Wire side of female terminalsHEATER CONTROL PANEL CONNECTOR B (20P)YEL/GRNWHT/BLURED/YELRED/BLUYEL/BLUYEL/RED

Is there any voltage?


YES - Repair any short to power in the wire(s) between the heater control panel and the mode control motor. This short also damages the heater control panel. Repair the short to power before replacing the heater control panel.n


NO - Go to 5.

5.Turn the ignition switch OFF, and check for continuity between the following terminals of heater control panel connectors A (12P) and B (20P) and the mode control motor 7P connector.

12P: 7P: 
No. 3 No. 7 


20P: 7P: 
No. 2 No. 3 
No. 3 No. 4 
No. 5 No. 5 
No. 6 No. 6 
No. 13 No. 2 
No. 15 No. 1 

 

S7A1E00K73100081100FAAD05HEATER CONTROL PANEL CONNECTOR A (12P)HEATER CONTROL PANEL CONNECTOR B (20P)Wire side of female terminalsWire side of female terminalsRED/YELYEL/GRNWHT/BLUWHT/
BLU
YEL/GRNRED/BLURED/YELRED/
BLU
LT GRNLT GRNMODE CONTROL MOTOR 7P CONNECTORWire side of female terminalsYEL/REDYEL/REDYEL/BLUYEL/BLU

Is there continuity?


YES - Check for loose wires or poor connections at heater control panel connectors A (12P) and B (20P) and at the mode control motor 7P connector. If the connections are good, substitute a known-good heater control panel, and recheck. If the symptom/indication goes away, replace the original heater control panel.n


NO - Repair any open in the wire(s) between the heater control panel and the mode control motor.n