DTC Troubleshooting: 13
DTC Troubleshooting: 13
| DTC 13: | An Open in the Evaporator Temperature Sensor Circuit |
| 1. | Remove the evaporator temperature sensor. |
| 2. | Measure the resistance between the No. 1 and No. 2 terminals of the evaporator temperature sensor. *Dip the sensor in ice water, and measure resistance. Then pour hot water on the sensor, and check for change in resistance.
5020 6830 °C 86 °FTEMPERATURERESISTANCE kW10203040EVAPORATOR TEMPERATURE SENSORTerminal side of male terminals Is the resistance within the specifications shown on the graph? YES - Go to 3. NO - Replace the evaporator temperature sensor.n |
| 3. | Disconnect heater control panel connector B (20P). |
| 4. | Check for continuity between the No. 7 terminal of heater control panel connector B (20P) and the No. 2 terminal of the evaporator temperature sensor 2P connector.
Is there continuity? YES - Go to 5. NO - Repair open in the wire between the heater control panel and the evaporator temperature sensor.n |
| 5. | Disconnect heater control panel connector A (12P). |
| 6. | Check for continuity between the No. 3 terminal of heater control panel connector A (12P) and the No. 1 terminal of the evaporator temperature sensor 2P connector.
Is there continuity? YES - Check for loose wires or poor connections at heater control panel connectors A (12P) and B (20P) and at the evaporator temperature sensor 2P connector. If the connections are good, substitute a known-good heater control panel, and recheck. If the symptom/indication goes away, replace the original heater control panel.n NO - Repair open in the wire between the heater control panel and the evaporator temperature sensor.n |