DTC Troubleshooting: P1709 (24) (5AT)
DTC Troubleshooting: P1709 (24)
| DTC P1709: | Problem in A/T Shift Switch Circuit |
NOTE: Record all freeze data before you troubleshoot.
| 1. | Turn the ignition switch OFF. |
| 2. | Remove the shift lever console panel. |
| 3. | Remove the mounting bolts securing the shift lever assembly, if necessary. |
| 4. | Remove the A/T shift switch/shift lock solenoid connector (8P) from the shift lever, then disconnect the 8P connector. |
| 5. | Turn the ignition switch ON (II). |
| 6. | Measure the voltage between the No. 3 terminal of the A/T shift switch/shift lock solenoid connector (8P) and body ground.
SOLENOID CONNECTOR (8P)Wire side of female terminalsS-MODE (BRN) Is there battery voltage? YES - Go to 7. NO - Repair open or short in the wire between PCM connector terminal D2 and the A/T shift switch/shift lock solenoid connector (8P).n |
| 7. | Measure the voltage between the No. 2 and No. 3 terminals of the A/T shift switch/shift lock solenoid connector (8P).
SOLENOID CONNECTOR (8P)Wire side of female terminalsS-MODE (BRN)(BLK) Is there battery voltage? YES - Go to 8. NO - Repair open in the wire between the No. 2 terminal of the A/T shift switch/shift lock solenoid connector (8P) and ground (G451), or repair poor ground ( G451).n |
| 8. | Measure the voltage between the No. 7 and No. 2 terminals of the A/T shift switch/shift lock solenoid connector (8P), and between the No. 8 and No. 2.
SOLENOID CONNECTOR (8P)Wire side of female terminals(BLK)S-UP (WHT/BLU)S-DN (BRN/WHT) Is there battery voltage between No. 7 and No. 2 terminals, and is there about 5 V between No. 8 and No. 2 terminals? YES - Go to 9. NO - Repair open in the wires between PCM connector terminals D3 and D9 and the A/T shift switch/shift lock solenoid connector (8P).n |
| 9. | Turn the ignition switch OFF. |
| 10. | Disconnect PCM connector D (17P). |
| 11. | Check for continuity between PCM connector terminals D3 and body ground, and between D9 and body ground.
Is there continuity? YES - Repair short to ground in the wire between PCM connector terminals D3 or D9 and the A/T shift switch/shift lock solenoid connector (8P).n NO - Go to 12. |
| 12. | Check for continuity between the No. 2 and No. 3 terminal at the A/T shift switch/shift lock solenoid connector (8P) when the shift lever shifts into [M] position, and when the shift lever shifts back to [D].
SOLENOID CONNECTOR (8P)Terminal side of male terminalsS-MODE (ORN)(BLK) Is there continuity when the shift lever in [M] position, and no continuity when the shift lever in [D]? YES - Go to 13. NO - Replace the A/T shift switch.n |
| 13. | Check for continuity between the No. 2 and No. 7 terminals of the A/T shift switch/shift lock solenoid connector (8P) while shifting the shift lever to shift-up position (marked with +), and between the No. 2 and No. 8 terminals while shifting to shift-down position (marked with -), and also check for continuity these terminals when the shift lever shifts back to neutral position.
SOLENOID CONNECTOR (8P)Terminal side of male terminalsS-DN(WHT/BLU) KB, KD, KG, KH, KK, KR (BLU/YEL) KE, KUS-UP(BLU/YEL) KB, KD, KG, KH, KK, KR (WHT/BLU) KE, KU(BLK) Is there continuity when the shift lever shifts to shift-up and shift-down positions, and no continuity when the shift lever shift back to neutral position? YES - Check for loose terminal fit in the PCM connectors. If necessary, substitute a known-good PCM and recheck.n NO - Replace the A/T shift switch.n |