A/C System Charging
A/C System Charging
|
- Use only a gauge set for refrigerant HFC-134a (R-134a).
- Use a vacuum pump adapter which is equipped with a check valve to prevent the backflow of the vacuum pump oil.
If accidental system discharge occurs, ventilate work area before resuming service.
Additional health and safety information may be obtained from the refrigerant and lubricant manufacturers.
| 1. | After the leak test, check that the high-pressure valve is closed, and start the engine. Run the engine below 1,500 rpm (min-1).
VALVEVACUUM PUMPHIGH-PRESSURE QUICK JOINTCHECK VALVELOW-PRESSURE QUICK JOINTR- 134aR- 134a
VALVEVACUUM PUMPHIGH-PRESSURE QUICK JOINTCHECK VALVELOW-PRESSURE QUICK JOINTEVACUATION STOP VALVER- 134aR- 134a |
| 2. | Open the front doors. Turn the A/C switch ON. Set the temperature control dial on MAX COOL. Set the mode control switch on VENT. Turn the fan switch on MAX. |
| 3. | Open the low-pressure valve, and charge with R-134a refrigerant.
|
| 4. | Charge the system with refrigerant capacity. Do not overcharge the system; the compressor will be damaged.
| ||||||||
| 5. | When fully charged, close the low-pressure valve and the refrigerant cans. Check the system. |
| 6. | Stop the engine, and disconnect the charge hose quickly. |
| 7. | Check the system for leaks using a leak detector proper to refrigerant R-134a. Particularly check for leaks around the compressor, condenser and receiver/dryer. |