Honda STREAM 2002 · Service Manual

DTC Troubleshooting: 7

DTC Troubleshooting: 7

DTC 7:  An Open in the Air Mix Control Motor Circuit


1.Disconnect the air mix control motor 7P connector.

2.Disconnect climate control unit connectors A (12P) and B (20P).

3.Check for continuity between following terminals of climate control unit connectors A (12P) and B ( 20P) and the air mix control motor 7P connector.

12P: 7P: 
No. 3 No. 7 
No. 12 No. 3 


20P: 7P: 
No. 4 No. 5 
No. 16 No. 2 
No. 17 No. 1 

 

S7A1E00K71100081070FAAD01Wire side of female terminalsWire side of female terminalsAIR MIX CONTROL
MOTOR 7P CONNECTOR
Wire side of female terminalsGRNPNK/BLUGRNGRYGRYPNK/BLUPNK/BLKPNK/BLKLT GRNLT GRNCLIMATE CONTROL UNIT CONNECTOR A (12P)CLIMATE CONTROL UNIT CONNECTOR B (20P)

Is there continuity?


YES - Check for loose wires or poor connections at climate control unit connectors A (12P) and B (20P) and at the air mix control motor 7P connector. If the connections are good, substitute a known-good  climate control unit, and recheck. If the symptom/indication goes away, replace the original  climate control unit.n


NO - Repair any open in he wire(s) between the  climate control unit and the air mix control motor.n