Honda STREAM 2002 · Service Manual

DTC Troubleshooting: 10

DTC Troubleshooting: 10

DTC 10:  An Open or Short in the Mode Control Motor Circuit


1.Disconnect the mode control motor 7P connector.

2.Disconnect climate control unit connectors A (12P) and B (20P).

3.Check for continuity between body ground and climate control unit connector A (12P) terminals No. 3, and between body ground and climate control unit connector B (20P) terminals No. 2, 3, 5, 6, 13 and 15 individually.

 

S7A1E00K71100081100FAAD01LT GRNWire side of female terminalsLT GRNCLIMATE CONTROL UNIT CONNECTOR A (12P)

 

S7A1E00K71100081100FAAD02YEL/GRNWHT/BLURED/YELRED/BLUYEL/BLUYEL/REDWire side of female terminalsCLIMATE CONTROL UNIT CONNECTOR B (20P)

Is there continuity?


YES - Repair any short to body ground in the wire(s) between the  climate control unit and the mode control motor.n


NO - Go to 4.

4.Turn the ignition switch ON (II), and check the same terminals for voltage.

 

S7A1E00K71100081100FAAD03LT GRNWire side of female terminalsLT GRNCLIMATE CONTROL UNIT CONNECTOR A (12P)

 

S7A1E00K71100081100FAAD04YEL/GRNWHT/BLURED/YELRED/BLUYEL/BLUYEL/REDWire side of female terminalsCLIMATE CONTROL UNIT CONNECTOR B (20P)

Is there any voltage?


YES - Repair any short to power in the wire(s) between the  climate control unit and the mode control motor. This short also damages the  climate control unit. Repair the short to power before replacing the  climate control unit.n


NO - Go to 5.

5.Turn the ignition switch OFF,and check for continuity between following terminals of climate control unit connectors A (12P) and B (20P) and the mode control motor 7P connector.

12P: 7P: 
No. 3 No. 7 


20P: 7P: 
No. 2 No. 3 
No. 3 No. 4 
No. 5 No. 5 
No. 6 No. 6 
No. 13 No. 2 
No. 15 No. 1 

 

S7A1E00K71100081100FAAD05Wire side of female terminalsWire side of female terminalsRED/YELYEL/GRNWHT/BLUWHT/
BLU
YEL/GRNRED/BLURED/YELRED/
BLU
LT GRNLT GRNMODE CONTROL MOTOR 7P CONNECTORWire side of female terminalsCLIMATE CONTROL UNIT CONNECTOR A (12P)CLIMATE CONTROL UNIT CONNECTOR B (20P)YEL/REDYEL/BLUYEL/REDYEL/BLU

Is there continuity?


YES - Check for loose wires or poor connections at climate control unit connectors A (12P) and B (20P) and at the mode control motor 7P connector. If the connections are good, substitute a known-good  climate control unit, and recheck. If the symptom/indication goes away, replace the original  climate control unit.n


NO - Repair any open in the wire(s) between the  climate control unit and the mode control motor.n