Lock-up Valve Body Disassembly, Inspection, and Reassembly (4AT)
Lock-up Valve Body Disassembly, Inspection, and Reassembly
| 1. | Clean all parts thoroughly in solvent or carburetor cleaner, and dry them with compressed air. Blow out all passages. |
| 2. | Check all valves for free movement. If any fail to slide freely, refer to Valve Body Repair. |
| 3. | Replace the valve body as an assembly if any parts are worn or damaged. |
| 4. | Coat all parts with ATF during assembly.
Inspect for scoring and damage.LOCK-UP TIMING VALVEVALVE CAP CLIPVALVE CAP(2)(1)ROLLER
| ||||||||||||||||||||||