| 4. | Measure wear and taper in direction X and Y at three levels in each cylinder as shown. If measurements in any cylinder are beyond the Oversize Bore Service Limit, replace the block. If the block is to be rebored, refer to 7 after reboring.
Cylinder Bore Size:| Standard (New): |
|---|
| | A or I: | 86.010-86.020 mm (3.3862-3.3866 in.) | | | B or II: | 86.000-86.010 mm (3.3858-3.3862 in.) | | | Service Limit: | 86.070 mm (3.3886 in.) |
| Oversize: |
|---|
| 0.25: | 86.250-86.260 mm (3.3957-3.3961 in.) |
| Reboring limit: | 0.25 mm (0.01 in.) max. |
| Bore Taper: |
|---|
| Limit: | (Difference between first and third measurement) 0.05 mm (0.002 in.) |
6 mm (0.2 in.)6 mm (0.2 in.)First MeasurementSecond MeasurementThird MeasurementXYNo. 4No. 1 |