Honda STREAM 2002 · Service Manual

Starter Solenoid Test (K20A)

Starter Solenoid Test

1.Check the hold-in coil for continuity between the S terminal (A) and the armature housing (ground). There should be continuity.

  • If there is continuity, go to 2.
  • If there is no continuity, replace the  solenoid.

 

S7A1E11A46500056941FEAD01AB

2.Check the pull-in coil for continuity between the S terminal (A) and M terminal (B). There should be continuity.

  • If there is continuity, the  solenoid is OK.