Heater Control Power and Ground Circuits Troubleshooting

Heater Control Power and Ground Circuits Troubleshooting

1.Check the No.14 (10A) fuse in the under-dash fuse/relay box.

Is the fuse OK?


YES - Go to 2.


NO - Replace the fuse, and recheck.n


2.Disconnect heater control panel connector A (12P).

3.Turn the ignition switch ON (II).

4.Measure the voltage between the No. 6 terminal of heater control panel connector A (12P) and body ground.

 

S7A1E00G24100031411FAAD01Wire side of female terminalsHEATER CONTROL PANEL CONNECTOR A (12P)BLK/YEL

Is there battery voltage?


YES - Go to 5.


NO - Repair open in the wire between the No. 14 fuse in the under-dash fuse/relay box and the heater control panel.n


5.Turn the ignition switch OFF.

6.Check for continuity between the No. 2 terminal of heater control panel connector A (12P) and body ground.

 

S7A1E00G24100031411FAAD02Wire side of female terminalsHEATER CONTROL PANEL CONNECTOR A (12P)BLK

Is there continuity?


YES - Check for loose wires or poor connections at heater control panel connector A (12P). If the connections are good, substitute a known-good heater control panel, and recheck. If the symptom/indication goes away, replace the original heater control panel.n


NO - Check for an open in the wire between the heater control panel and body ground. If the wire is OK, check for poor ground at  G502.n