Honda STREAM 2003 · Service Manual

Mode Control Motor Test

Mode Control Motor Test

1.Disconnect the 7P connector from the mode control motor.

2.Connect battery power to the No. 1 terminal of the mode control motor, and ground the No. 2 terminal; the mode control motor should run smoothly, and stop at Vent. If it doesn't, reverse the connections; the mode control motor should run smoothly, and stop at Defrost. When the mode control motor stops running, disconnect battery power immediately.

 

S80WA00G24100040301FEAD01MODE CONTROL MOTOR

3.Use a digital multimeter with an output of 1 mA or less at the 20 kW range. With the mode control motor running as in 2, check for continuity between the No. 3, 4, 5, 6 terminals and the No. 7 terminal individually. There should be continuity for a moment at each terminal.

4.If the mode control motor does not run in 2, remove it, then check the mode control linkage and doors for smooth movement.

  • If the linkage and doors move smoothly, replace the mode control motor.