Honda STREAM 2003 · Service Manual

DTC Troubleshooting: 5

DTC Troubleshooting: 5

DTC 5:  An Open in the Sunlight Sensor Circuit


1.Disconnect the sunlight sensor 2P connector.

2.Disconnect climate control unit connector B (20P).

3.Check for continuity between the No. 8 terminal of climate control unit connector B (20P) and the No. 1 terminal of the sunlight sensor 2P connector.

 

S7A1E00K71100081050FAAD01Wire side of female terminalsWire side of female terminalsSUNLIGHT SENSOR 2P CONNECTORCLIMATE CONTROL UNIT CONNECTOR B (20P)ORNORN

Is there continuity?


YES - Go to 4.


NO - Repair open in the wire between the  climate control unit and the  sunlight sensor.n


4.Disconnect climate control unit connector A (12P).

5.Check for continuity between the No. 3 terminal of climate control unit connector A (12P) and the No. 2 terminal of the sunlight sensor 2P connector.

 

S7A1E00K71100081050FAAD02Wire side of female terminalsWire side of female terminalsSUNLIGHT SENSOR 2P CONNECTORCLIMATE CONTROL UNIT CONNECTOR A (12P)LT GRNLT GRN

Is there continuity?


YES - Go to 6.


NO - Repair open in the wire between the  climate control unit and the  sunlight sensor.n


6.Reconnect the sunlight sensor 2P connector.

7.Reconnect climate control unit connectors A (12P) and B (20P).

8.Test the sunlight sensor.

Is the sunlight sensor OK?


YES - Check for loose wires or poor connections at climate control unit connectors A (12P) and B (20P) and at the sunlight sensor 2P connector. If the connections are good, substitute a known-good  climate control unit, and recheck. If the symptom/indication goes away, replace the original  climate control unit.n


NO - Replace the  sunlight sensor.n