Honda STREAM 2003 · Service Manual

DTC Troubleshooting: 13

DTC Troubleshooting: 13

DTC 13:  An Open in the Evaporator Temperature Sensor Circuit


1.Remove the evaporator temperature sensor.

2.Measure the resistance between the No. 1 and No. 2 terminals of the  evaporator temperature sensor.
*Dip the sensor in ice water, and measure resistance. Then pour hot water on the sensor, and check for change in resistance.

 

S5A1E4AK71100081140FAAD01EVAPORATOR TEMPERATURE SENSORTerminal side of male terminals10
50
20
68
30 °C
86 °F
TEMPERATURERESISTANCE
kW
10203040

Is the resistance within the specifications shown on the graph?


YES - Go to 3.


NO - Replace the  evaporator temperature sensor.n


3.Disconnect climate control unit connector B (20P).

4.Check for continuity between the No. 7 terminal of climate control unit connector B (20P) and the No. 2 terminal of the evaporator temperature sensor 2P connector.

 

S7A1E00K71100081130FAAD01Wire side of female terminalsBRNBRNEVAPORATOR TEMPERATURE SENSOR 2P CONNECTORWire side of female terminalsCLIMATE CONTROL UNIT CONNECTOR B (20P)Wire side of female terminals

Is there continuity?


YES - Go to 5.


NO - Repair open in the wire between the  climate control unit and the  evaporator temperature sensor.n


5.Disconnect climate control unit connector A (12P).

6.Check for continuity between the No. 3 terminal of climate control unit connector A (12P) and the No. 1 terminal of the evaporator temperature sensor 2P connector.

 

S7A1E00K71100081130FAAD02LT GRNLT GRNWire side of female terminalsEVAPORATOR TEMPERATURE SENSOR 2P CONNECTORWire side of female terminalsCLIMATE CONTROL UNIT CONNECTOR A (12P)Wire side of female terminals

Is there continuity?


YES - Check for loose wires or poor connections at climate control unit connectors A (12P) and B (20P) and at the evaporator temperature sensor 2P connector. If the connections are good, substitute a known-good  climate control unit, and recheck. If the symptom/indication goes away, replace the original  climate control unit.n


NO - Repair open in the wire between the climate control unit and the evaporator temperature sensor.n