Honda STREAM 2003 · Service Manual

DTC Troubleshooting: 13

DTC Troubleshooting: 13

DTC 13:  An Open in the Evaporator Temperature Sensor Circuit


1.Remove the evaporator temperature sensor.

2.Measure the resistance between the No. 1 and No. 2 terminals of the  evaporator temperature sensor.
*Dip the sensor in ice water, and measure resistance. Then pour hot water on the sensor, and check for change in resistance.

 

S5A1E4EK73100081140FAAD0110
50
20
68
30 °C
86 °F
TEMPERATURERESISTANCE
kW
10203040EVAPORATOR TEMPERATURE SENSORTerminal side of male terminals

Is the resistance within the specifications shown on the graph?


YES - Go to 3.


NO - Replace the  evaporator temperature sensor.n


3.Disconnect heater control panel connector B (20P).

4.Check for continuity between the No. 7 terminal of heater control panel connector B (20P) and the No. 2 terminal of the evaporator temperature sensor 2P connector.

 

S7A1E00K73100081130FAAD01Wire side of female terminalsHEATER CONTROL PANEL CONNECTOR B (20P)BRNBRNWire side of female terminalsEVAPORATOR TEMPERATURE SENSOR 2P CONNECTOR

Is there continuity?


YES - Go to 5.


NO - Repair open in the wire between the heater control panel and the  evaporator temperature sensor.n


5.Disconnect heater control panel connector A (12P).

6.Check for continuity between the No. 3 terminal of heater control panel connector A (12P) and the No. 1 terminal of the evaporator temperature sensor 2P connector.

 

S7A1E00K73100081130FAAD02Wire side of female terminalsWire side of female terminalsEVAPORATOR TEMPERATURE SENSOR 2P CONNECTORHEATER CONTROL PANEL CONNECTOR A (12P)LT GRNLT GRN

Is there continuity?


YES - Check for loose wires or poor connections at heater control panel connectors A (12P) and B (20P) and at the evaporator temperature sensor 2P connector. If the connections are good, substitute a known-good heater control panel, and recheck. If the symptom/indication goes away, replace the original heater control panel.n


NO - Repair open in the wire between the heater control panel and the  evaporator temperature sensor.n