Honda STREAM 2004 · Service Manual

Air Mix Control Motor Test

Air Mix Control Motor Test

1.Disconnect the 7P connector from the air mix control motor.

2.Connect battery power to the No. 1 terminal of the air mix control motor, and ground the No. 2 terminal; the air mix control motor should run smoothly, and stop at Max Hot. If it doesn't, reverse the connections; the air mix control motor should run smoothly, and stop at Max Cool. If the air mix control motor does not run, remove it, then check the air mix control linkage and door for smooth movement.

  • If the linkage and door move smoothly, replace the air mix control motor.
  • If the linkage or door sticks or binds, repair them as needed.

 

S80WA00G24100012701FEAD01AIR MIX CONTROL MOTOR

3.Measure the resistance between the No. 5 and No. 7 terminals. It should be between 4.2 k to 7.8 kW.

4.Measure the resistance between the No. 3 and No. 7 terminals.

Max Cool-0.84 k to 1.56 kW 
Max Hot-3.36 k to 6.24 kW