Recirculation Control Motor Circuit Troubleshooting - Without Climate Control

Recirculation Control Motor Circuit Troubleshooting - Without Climate Control

1.Check the No. 14 (10A) fuse in the under-dash fuse/relay box.

Is the fuse OK?


YES - Go to 2.


NO - Replace the fuse, and recheck.n


2.Disconnect the recirculation control motor 7P connector.

3.Turn the ignition switch ON (II).

4.Measure the voltage between the No. 1 terminal of the recirculation control motor 7P connector and body ground.

 

S5A1A00G24100050602FAAD01RECIRCULATION CONTROL MOTOR
7P CONNECTOR
Wire side of female terminalsBLK/YEL

Is there battery voltage?


YES - Go to 5.


NO - Repair open in the wire between the No. 14 fuse in the under-dash fuse/relay box and the recirculation control motor.n


5.Turn the ignition switch OFF.

6.Test the recirculation control motor.

Is the recirculation control motor OK?


YES - Go to 7.


NO - Go to 12.


7.Disconnect heater control panel connector B (20P).

8.Check for continuity between the No. 18 and No. 19 terminals of heater control panel connector B (20P) and body ground individually.

 

S7A1E00G24100050602FAAD04Wire side of female terminalsHEATER CONTROL PANEL CONNECTOR B (20P)GRN/WHTGRN/YEL

Is there continuity?


YES - Repair any short to body ground in the wire(s) between the heater control panel and the recirculation control motor.n


NO - Go to 9.


9.Turn the ignition switch ON (II), and check the same wires for voltage.

 

S7A1E00G24100050602FAAD05Wire side of female terminalsHEATER CONTROL PANEL CONNECTOR B (20P)GRN/WHTGRN/YEL

Is there any voltage?


YES - Repair any short to power in the wire(s) between the heater control panel and the recirculation control motor. This short also damages the heater control panel. Repair the short to power before replacing the heater control panel.n


NO - Go to 10.

10.Turn the ignition switch OFF.

11.Check for continuity between the following terminals of heater control panel connector B (20P) and the recirculation control motor 7P connector.

20P: 7P: 
No. 18 No. 5 
No. 19 No. 7 

 

S7A1E00G24100050602FAAD06Wire side of female terminalsHEATER CONTROL PANEL CONNECTOR B (20P)Wire side of female terminalsRICIRCULATION CONTROL MOTOR 7P CONNECTORGRN/WHTGRN/YELGRN/YELGRN/WHT

Is there continuity?


YES - Check for loose wires or poor connections at heater control panel connector B (20P) and at the recirculation control motor 7P connector. If the connections are good, substitute a known-good heater control panel, and recheck. If the symptom/indication goes away, replace the original heater control panel.n


NO - Repair any open in the wire(s) between the heater control panel and the recirculation control motor.n

12.Remove the recirculation contol motor.

13.Check the recirculation control linkage and doors for smooth movement.

Do the recirculation control linkage and doors move smoothly?


YES - Replace the recirculation control motor.n


NO - Repair the recirculation control linkage or doors.n