Honda STREAM 2004 · Service Manual

Torque Converter Housing Mainshaft Bearing and Oil Seal Replacement (4AT)

Torque Converter Housing Mainshaft Bearing and Oil Seal Replacement

Special Tools Required
Adjustable bearing puller, 25-40 mm (  07736-A01000B)
 

S80WA00S736A01T000B000D01
or 07736-A01000ADriver (  07749-0010000)
 
S80WA00S749001T0000000D01
Attachment, 62 x 68 mm (  07746-0010500)
 
S80WA00S746001T0500000D01
Attachment, 72 x 75 mm (  07746-0010600)
 
S80WA00S746001T0600000D01



1.Remove the mainshaft bearing and oil seal with the special tool and a commercially available 3/8''-16 slide hammer (A).

 

S5A1A02E10411239521KBAD01A07736-A01000B or
07736-A01000A

2.Install the new mainshaft bearing until it bottoms in the housing with the special tools.

 

S5A1A02E10411239521KBAD0207749-001000007746-0010500

3.Install the new oil seal flush with the housing using special tools.

 

S5A1A02E10411239521KBAD0307749-001000007746-0010600