Honda STREAM 2004 · Service Manual

Gauges Self-diagnostic Procedure

Gauges Self-diagnostic Procedure

The gauge assembly has a self-diagnosis function.

Entering the self-diagnosis function

Before doing the self-diagnosis function, check the No. 9 (10A) fuse in the under-hood fuse/relay box and the No. 10 ( 7.5A) fuse in the under-dash fuse/relay box.

1.Push and hold the trip/reset button.

2.Turn the lighting switch ON.

3.Turn the ignition switch ON (II).

4.Within 5 sec., turn the lighting switch OFF, then ON and OFF again.

5.Within 5 sec., release the trip/reset button, then push and release the button three times repeatedly.

NOTE:

 

S7A4ET0J22100000000BBAD015 sec.5 sec.Move to self-diagnosis mode.OFFOFFOFFIgnitionSwitchLightingSwitchTrip/ResetSwitchON (II)ONON

The Beeper Drive Circuit Check

When entering the self-diagnosis mode, the beeper sounds five times.

The Indicator Drive Circuit Check

When entering the self-diagnosis mode, the indicator lights blink.
The following indicators blink:
Seat belt indicator light, Charging system light, Low fuel indicator light, Maintenance required indicator light, Door indicator light, Tailgate indicator light, Brake system light, A/T gear position indicator lights (expect P, D, N).

Switch Input Check

After the intermittent beeper sounds at the initial stage of self-diagnosis, a beeper sounds continuously while any of the following switch inputs are switched from OFF to ON.
The following switches cause the beeper sounds:
Rear fog light switch.

The LCD Segment Check

When entering the self-diagnosis mode, the odo/trip segments and outside air temperature segment blink five times.

The Gauge Drive Circuit Check

When entering the self-diagnosis mode, the speedometer, the tachometer, the fuel gauge, and the coolant temperature gauge needles sweep from the minimum position to maximum position, then return to the minimum position.

NOTE:
After the beeper stops sounding and the gauge needles return to the minimum position, pushing the trip/reset button starts the Beeper Drive Circuit Check (one beep) and the Gauge Drive Circuit Check again.
The check cannot be started again until the gauge needles return to the minimum position.

 

S7A4ET0J22100000000BBAD02Trip/Reset
switch
Self-diagnosis
mode
The needles sweep from the
minimum position to the
maximum position, then
return to the minimum position.

If a needle fails to sweep or the beeper does not sound, replace the gauge control module.

The Communication Line Check

In the self-diagnosis mode, after the odo/trip LCD Segments Check, the self-diagnosis starts the Communication Line Check.
If all segments comes on, the communication line is OK.
If the word ‘‘Error'' is indicated, there is a malfunction communication line between the gauge assembly, the multiplex control unit, and the PCM.

 

S7A4ET0J22100000000BBAD03Normal:Faulty:

Ending the self-diagnosis function

Turn the ignition switch OFF.
NOTE: If the vehicle speed exceeds 2 km/h (1.2 mph), the self-diagnosis function ends.