DTC    P0A93-346    Inverter Cooling System Performance


DESCRIPTION

INSPECTION PROCEDURE

CHECK DTC OUTPUT (HYBRID CONTROL)

CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

CHECK QUANTITY OF HV COOLANT

CHECK COOLANT HOSE

PERFORM ACTIVE TEST USING INTELLIGENT TESTER (CONTROL THE ELECTRIC COOLING FAN)

READ VALUE USING INTELLIGENT TESTER

CHECK HV COOLANT (CHECK FOR CONDITIONS THAT MAY HAVE CAUSED FREEZING)

REPLACE HV COOLANT

CHECK INVERTER WATER PUMP ASSEMBLY