DTC P0010 Camshaft Position "A" Actuator Circuit (Bank 1) |

| DTC No. | DTC Detection Condition | Trouble Area |
| P0010 | Open or short in camshaft timing oil control valve assembly circuit (1 trip detection logic). |
|

| 1.PERFORM ACTIVE TEST USING INTELLIGENT TESTER (OPERATE CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY) |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Turn the tester on.
Put the engine in inspection mode (maintenance mode) (Click here).
Start the engine.
Enter the following menus: Powertrain / Engine and ECT / Active Test / Control the VVT Linear (Bank 1).
Check the engine speed while operating the camshaft timing oil control valve assembly using the tester.
| Tester Operation | Specified Condition |
| 0% | Normal engine speed |
| 100% | Engine idles roughly or stalls |
|
| ||||
| OK | ||
| ||
| 2.INSPECT CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY |
Inspect the camshaft timing oil control valve assembly (Click here).
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY - ECM) |
Disconnect the camshaft timing oil control valve assembly connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D24-1 (+) - D27-36 (OC1+) | Always | Below 1 Ω |
| D24-2 (-) - D27-59 (OC1-) | Always | Below 1 Ω |
| D24-1 (+) or D27-36 (OC1+) - Body ground | Always | 10 kΩ or higher |
| D24-2 (-) or D27-59 (OC1-) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||