LIGHTING SYSTEM > FAIL-SAFE CHART |
| LED HEADLIGHT SYSTEM |
| Item | Abnormality Detection Condition | Return Condition | Master Warning Light | Multi-information Display |
| Abnormal input voltage (High input voltage) | Abnormal power source voltage (more than 17 V) is detected. | Normal power source voltage (10 to 16 V) is detected. | Flashes | CHECK HEADLIGHT SYSTEM |
| Abnormal input voltage (Low input voltage) | Abnormal power source voltage (less than 10 V) is detected. | Normal power source voltage (10 to 16 V) is detected. | Flashes | CHECK HEADLIGHT SYSTEM |
| Abnormal output |
| Light control switch is turned off. | Flashes | CHECK HEADLIGHT SYSTEM |
| AUTOMATIC LIGHT CONTROL SYSTEM |
| AUTOMATIC HEADLIGHT BEAM LEVEL CONTROL SYSTEM |
The headlight leveling ECU assembly operates in fail-safe mode if an abnormal condition such as those listed below has been detected, and keep the last low beam status.
| Item | Abnormality Detection Condition | Return Condition | Warning Indicator |
| Height control sensor power source voltage | Abnormal height control sensor power source voltage (4.6 V or less) is detected. | Abnormal voltage is not detected for 5 seconds consecutively | Illuminated |
| Height control sensor signal voltage | Abnormal height control sensor signal voltage (0.25 V or less, or 4.75 V or more) is detected. | ||
| High power source voltage | Abnormal high ignition voltage (18.5 V or more) is detected. | Voltage of 17.5 V or less is detected | Not illuminated |
| Low power source voltage | Abnormal low ignition voltage (9.0 V or less) is detected. | Voltage of 9.3 V or more is detected for 0.1 seconds consecutively | Not illuminated |
| Reset while running | Reset by a temporary blackout etc. while running. | Vehicle is stopped | Not illuminated |