DTC B1443/43 Air Outlet Damper Control Servo Motor Circuit |
| DTC No. | DTC Detection Condition | Trouble Area |
| B1443/43 | Air outlet damper position sensor value does not change even if air conditioning amplifier assembly operates air outlet control servo motor |
|

| 1.READ VALUE USING INTELLIGENT TESTER |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Turn the intelligent tester on.
Operate the MODE switch.
Enter the following menus: Body / Air Conditioner / Data List.
Check the value(s) by referring to the table below.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Air Outlet Servo Pulse (D) | Air outlet servo motor target pulse / Min.: 0, Max.: 255 | FACE: 47 (pulse) B/L: 37 (pulse) FOOT: 18 or 23 (pulse) FOOT/DEF: 9 (pulse) DEF: 5 (pulse) | - |
| Air Outlet Servo Actu Pulse (D) | Air outlet servo motor actual pulse / Min.: 0, Max.: 255 | FACE: 47 (pulse) B/L: 37 (pulse) FOOT: 18 or 23 (pulse) FOOT/DEF: 9 (pulse) DEF: 5 (pulse) | - |
| Result | Proceed to |
| NG | A |
| OK (When troubleshooting according to Problem Symptoms Table) | B |
| OK (When troubleshooting according to the DTC) | C |
|
| ||||
|
| ||||
| A | |
| 2.PERFORM ACTIVE TEST USING INTELLIGENT TESTER |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Turn the intelligent tester on.
Enter the following menus: Body / Air Conditioner / Active Test.
Check the operation by referring to the table below.
| Tester Display | Test Part | Control Rage | Diagnostic Note |
| Air Outlet Servo Pulse (D) | Air outlet servo motor pulse | Min.: 0, Max.: 255 | - |
|
| ||||
| OK | ||
| ||
| 3.INSPECT AIR OUTLET CONTROL SERVO MOTOR |
Replace the air outlet control servo motor (Click here).
Check for the DTC.
| Result | Proceed to |
| DTC B1443/43 is output | A |
| DTC B1443/43 is not output | B |
|
| ||||
| A | |
| 4.INSPECT AIR CONDITIONING HARNESS ASSEMBLY |
Replace the air conditioning harness assembly (Click here).
Check for the DTC.
| Result | Proceed to |
| DTC B1443/43 is output | A |
| DTC B1443/43 is not output | B |
|
| ||||
| A | ||
| ||