SLIDING ROOF SYSTEM > TERMINALS OF ECU |
| CHECK SLIDING ROOF ECU (SLIDING ROOF DRIVE GEAR ASSEMBLY) |
Disconnect the T10 sliding roof ECU (sliding roof drive gear assembly) connector.

Measure the resistance and voltage according to the value(s) in the table below.
| Tester Connection | Wiring Color | Terminal Description | Condition | Specified Condition |
| T10-1 (B) - T10-2 (E) | R - W-B | +B Power supply | Power switch off | 11 to 14 V |
| T10-5 (IG) - T10-2 (E) | L - W-B | Power switch power supply | Power switch off | Below 1 V |
| T10-5 (IG) - T10-2 (E) | L - W-B | Power switch power supply | Power switch on (IG) | 11 to 14 V |
| T10-2 (E) - Body ground | W-B - Body ground | Ground | Always | Below 1 Ω |
Reconnect the T10 sliding roof ECU (sliding roof drive gear assembly) connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Wiring Color | Terminal Description | Condition | Specified Condition |
| T10-7 (OPN) - T10-2 (E) | SB - W-B | Sliding roof motor open | Power switch on (IG), SLIDE OPEN switch ON | Below 1 V |
| T10-7 (OPN) - T10-2 (E) | SB - W-B | Sliding roof motor open | Power switch on (IG), SLIDE OPEN switch OFF | 11 to 14 V |
| T10-9 (CLS) - T10-2 (E) | BR - W-B | Sliding roof motor close | Power switch on (IG), SLIDE CLOSE switch ON | Below 1 V |
| T10-9 (CLS) - T10-2 (E) | BR - W-B | Sliding roof motor close | Power switch on (IG), SLIDE CLOSE switch OFF | 11 to 14 V |
| T10-10 (UP) - T10-2 (E) | B - W-B | Sliding roof motor up | Power switch on (IG), TILT UP switch ON | Below 1 V |
| T10-10 (UP) - T10-2 (E) | B - W-B | Sliding roof motor up | Power switch on (IG), TILT UP switch OFF | 11 to 14 V |
| T10-8 (DWN) - T10-2 (E) | R - W-B | Sliding roof motor down | Power switch on (IG), TILT DOWN switch ON | Below 1 V |
| T10-8 (DWN) - T10-2 (E) | R - W-B | Sliding roof motor down | Power switch on (IG), TILT DOWN switch OFF | 11 to 14 V |