LUMBAR SWITCH > INSPECTION

for Preparation Click here



1. INSPECT LUMBAR SUPPORT ADJUSTMENT SWITCH (POWER SEAT SWITCH ASSEMBLY) (for LHD)


B239575E08
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    3 - 5
    Hold
    Below 1 Ω
    1 - 2
    2 - 3
    Off
    1 - 2
    2 - 3
    Release
    1 - 5

    Text in Illustration 
    *1
    Hold Switch
    *2
    Release Switch
    *a
    Component without harness connected
    (Lumbar Support Adjustment Switch (Power Seat Switch Assembly))
    If the result is not as specified, replace the lumbar support adjustment switch (power seat switch assembly).



2. INSPECT LUMBAR SUPPORT ADJUSTMENT SWITCH (POWER SEAT SWITCH ASSEMBLY) (for RHD)


B239575E09
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    1 - 5
    Hold
    Below 1 Ω
    2 - 3
    2 - 3
    Off
    1 - 2
    3 - 5
    Release
    1 - 2

    Text in Illustration 
    *1
    Hold Switch
    *2
    Release Switch
    *a
    Component without harness connected
    (Lumbar Support Adjustment Switch (Power Seat Switch Assembly))
    If the result is not as specified, replace the lumbar support adjustment switch (power seat switch assembly).