DYNAMIC RADAR CRUISE CONTROL SYSTEM > Millimeter Wave Radar Sensor Power Source Circuit |

| 1.CHECK MILLIMETER WAVE RADAR SENSOR ASSEMBLY (IGB VOLTAGE) |
![]() |
Disconnect the millimeter wave radar sensor assembly connector.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A2-5 (IGB) - A2-2 (SGND) | Power switch on (IG) | 10 to 14 V |
| *a | Front view of wire harness connector (to Millimeter Wave Radar Sensor Assembly) |
Reconnect the millimeter wave radar sensor assembly connector.
|
| ||||
| OK | ||
| ||
| 2.CHECK HARNESS AND CONNECTOR (MILLIMETER WAVE RADAR SENSOR ASSEMBLY - BODY GROUND) |
![]() |
Disconnect the millimeter wave radar sensor assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| A2-2 (SGND) - Body ground | Always | Below 1 Ω |
| *a | Front view of wire harness connector (to Millimeter Wave Radar Sensor Assembly) |
Reconnect the millimeter wave radar sensor assembly connector.
|
| ||||
| OK | ||
| ||