RELAY > ON-VEHICLE INSPECTION |
| 1. INSPECT FUEL OPN RELAY |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 3 - 5 | Battery voltage applied to terminals 1 and 2 | Below 1 Ω |
| 3 - 5 | Battery voltage not applied between terminals 1 and 2 | 10 kΩ or higher |