DTC B2006 Short to GND in Seat Belt Motor LH Circuit |
| DTC No. | DTC Detection Condition | Trouble Area |
| B2006 | Short to ground in the seat belt motor LH circuit continues for 1 second or more. |
|

| 1.INSPECT FRONT SEAT OUTER BELT ASSEMBLY LH |
![]() |
Remove the front seat outer belt assembly LH connector (Click here).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| P11-1 - Body ground | Always | 1 MΩ or higher |
| P11-2 - Body ground | Always | 1 MΩ or higher |
Reconnect the front seat outer belt assembly LH connector.
|
| ||||
| OK | |
| 2.CHECK HARNESS AND CONNECTOR (FRONT SEAT OUTER BELT ASSEMBLY LH - SEAT BELT CONTROL ECU) |
Disconnect the cable from the negative (-) auxiliary battery terminal.
Disconnect the front seat outer belt assembly LH connector.
Disconnect the seat belt control ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| P11-1 - Body ground | Always | 1 MΩ or higher |
| P11-2 - Body ground | Always | 1 MΩ or higher |
| P11-1 - P11-2 | Always | 1 MΩ or higher |
Reconnect the front seat outer belt assembly LH and seat belt control ECU connectors.
Connect the cable to the negative (-) auxiliary battery terminal.
|
| ||||
| OK | ||
| ||