RELAY > ON-VEHICLE INSPECTION

for Preparation Click here



1. INSPECT FAN NO. 1 RELAY


    A252086E01
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    3 - 5
    Battery voltage is not applied between terminals 1 and 2
    10 kΩ or higher
    3 - 5
    Battery voltage is applied between terminals 1 and 2
    Below 1 Ω

    If the result is not as specified, replace the fan relay.



2. INSPECT FAN NO. 2 RELAY


    A159206E03
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    3 - 4
    Battery voltage is not applied between terminals 1 and 2
    Below 1 Ω
    3 - 4
    Battery voltage is applied between terminals 1 and 2
    10 kΩ or higher
    3 - 5
    Battery voltage is not applied between terminals 1 and 2
    10 kΩ or higher
    3 - 5
    Battery voltage is applied between terminals 1 and 2
    Below 1 Ω

    If the result is not as specified, replace the fan relay.



3. INSPECT FAN NO. 3 RELAY


    A252086E01
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    3 - 5
    Battery voltage is not applied between terminals 1 and 2
    10 kΩ or higher
    3 - 5
    Battery voltage is applied between terminals 1 and 2
    Below 1 Ω

    If the result is not as specified, replace the fan relay.