DTC    B1411/11    Room Temperature Sensor Circuit

for Preparation Click here


DESCRIPTION

The room temperature sensor is installed in the instrument panel. It detects the cabin temperature to control air conditioning AUTO mode. The resistance of the room temperature sensor changes in accordance with the cabin temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier assembly applies voltage (5 V) to the room temperature sensor and reads voltage changes as the resistance of the room temperature sensor changes. This sensor also sends appropriate signals to the air conditioning amplifier assembly.

DTC No.
DTC Detection Condition
Trouble Area
B1411/11
Open or short in room temperature sensor circuit
  1. Room temperature sensor
  2. Harness or connector between room temperature sensor and air conditioning amplifier assembly
  3. Air conditioning amplifier assembly

WIRING DIAGRAM


E219964E03


INSPECTION PROCEDURE

HINT:
If the cabin temperature is approximately -18.6°C (-1.48°F) or lower, DTC B1411/11 may be output even though the system is normal.

1.READ VALUE USING INTELLIGENT TESTER
  1. Connect the intelligent tester to the DLC3.

  1. Turn the power switch on (IG).

  1. Turn the intelligent tester on.

  1. Enter the following menus: Body / Air Conditioner / Data List.

  1. Check the value(s) by referring to the table below.

    Air Conditioner 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Room Temperature Sensor
    Room temperature sensor /
    Min.: -6.5°C (20.3°F)
    Max.: 57.25°C (135.05°F)
    Actual cabin temperature displayed
    -

    OK:
    The display is as specified in the Normal Condition column.


    Result:

    Result
    Proceed to
    NG
    A
    OK (When troubleshooting according to Problem Symptoms Table)
    B
    OK (When troubleshooting according to the DTC)
    C



B
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)

C
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY (Click here)
A


2.INSPECT ROOM TEMPERATURE SENSOR


    E161677E35
  1. Remove the room temperature sensor.

  1. Disconnect the H79 room temperature sensor connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    H79-1 (+) - H79-2 (-)
    10°C (50°F)
    3.00 to 3.73 kΩ
    H79-1 (+) - H79-2 (-)
    15°C (59°F)
    2.45 to 2.88 kΩ
    H79-1 (+) - H79-2 (-)
    20°C (68°F)
    1.95 to 2.30 kΩ
    H79-1 (+) - H79-2 (-)
    25°C (77°F)
    1.60 to 1.80 kΩ
    H79-1 (+) - H79-2 (-)
    30°C (86°F)
    1.28 to 1.47 kΩ
    H79-1 (+) - H79-2 (-)
    35°C (95°F)
    1.00 to 1.22 kΩ
    H79-1 (+) - H79-2 (-)
    40°C (104°F)
    0.80 to 1.00 kΩ
    H79-1 (+) - H79-2 (-)
    45°C (113°F)
    0.65 to 0.85 kΩ
    H79-1 (+) - H79-2 (-)
    50°C (122°F)
    0.50 to 0.70 kΩ
    H79-1 (+) - H79-2 (-)
    55°C (131°F)
    0.44 to 0.60 kΩ
    H79-1 (+) - H79-2 (-)
    60°C (140°F)
    0.36 to 0.50 kΩ

    NOTICE:
    1. Hold the sensor only by its connector. Touching the sensor may change the resistance value.
    2. When measuring, the sensor temperature must be the same as the ambient temperature.

    HINT:
    As the temperature increases, the resistance decreases (see the graph).

    Text in Illustration 
    *a
    Component without harness connected
    (Room Temperature Sensor)
    *b
    Sensing Portion
    *c
    Resistance (kΩ)
    *d
    Allowable Range
    *e
    Temperature (°C (°F))



NG
REPLACE ROOM TEMPERATURE SENSOR (Click here)
OK


3.CHECK HARNESS AND CONNECTOR (ROOM TEMPERATURE SENSOR - AIR CONDITIONING AMPLIFIER)
  1. Disconnect the H85 air conditioning amplifier assembly connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    H85-29 (TR) - H79-1 (+)
    Always
    Below 1 Ω
    H85-34 (SG-1) - H79-2 (-)
    Always
    Below 1 Ω
    H85-29 (TR) - Body ground
    Always
    10 kΩ or higher
    H85-34 (SG-1) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK