LIGHTING SYSTEM > Headlight Beam Level Control Actuator Circuit |

| 1.PERFORM ACTIVE TEST USING INTELLIGENT TESTER |
Connect the intelligent tester to the DLC3.
Turn the power switch on (READY).
Turn the intelligent tester on.
Enter the following menus: Body / HL Auto Leveling / Active Test.
Check that the leveling motors operate.
| Tester Display | Test Part | Control Range | Diagnostic Note |
| Drive The Leveling Motor UP | Leveling motor upward operation | ON/OFF | ON: Move up OFF: Stop |
| Drive The Leveling Motor DOWN | Leveling motor downward operation | ON/OFF | ON: Move down OFF: Stop |
|
| ||||
| OK | ||
| ||
| 2.CHECK HARNESS AND CONNECTOR (HEADLIGHT ASSEMBLY - HEADLIGHT LEVELING ECU ASSEMBLY) |
Disconnect the A46 headlight leveling ECU assembly connector.
Disconnect the A8 or A39 headlight assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| A8-8 (LHIG) - 3 | Always | Below 1 Ω |
| A8-3 (LHT) - 2 | Always | Below 1 Ω |
| A8-4 (LHE) - 1 | Always | Below 1 Ω |
| A8-8 (LHIG) - Body ground | Always | 10 kΩ or higher |
| A8-3 (LHT) - Body ground | Always | 10 kΩ or higher |
| A8-4 (LHE) - Body ground | Always | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
| A39-8 (RHIG) - 3 | Always | Below 1 Ω |
| A39-3 (RHT) - 2 | Always | Below 1 Ω |
| A39-4 (RHE) - 1 | Always | Below 1 Ω |
| A39-8 (RHIG) - Body ground | Always | 10 kΩ or higher |
| A39-3 (RHT) - Body ground | Always | 10 kΩ or higher |
| A39-4 (RHE) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | |
| 3.CHECK HEADLIGHT ASSEMBLY (HEADLIGHT ASSEMBLY - HEADLIGHT LEVELING MOTOR) |
Disconnect the LH side or RH side headlight leveling motor connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| A46-18 (LHT) - A8-3 (LHT) | Always | Below 1 Ω |
| A46-11 (LH+) - A8-8 (LHIG) | Always | Below 1 Ω |
| A46-24 (LH-) - A8-4 (LHE) | Always | Below 1 Ω |
| A46-18 (LHT) - Body ground | Always | 10 kΩ or higher |
| A46-11 (LH+) - Body ground | Always | 10 kΩ or higher |
| A46-24 (LH-) - Body ground | Always | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
| A46-17 (RHT) - A39-3 (RHT) | Always | Below 1 Ω |
| A46-10 (RH+) - A39-8 (RHIG) | Always | Below 1 Ω |
| A46-23 (RH-) - A39-4 (RHE) | Always | Below 1 Ω |
| A46-17 (RHT) - Body ground | Always | 10 kΩ or higher |
| A46-10 (RH+) - Body ground | Always | 10 kΩ or higher |
| A46-23 (RH-) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | |
| 4.REPLACE HEADLIGHT LEVELING MOTOR |
Replace the headlight leveling motor with a new or a known good one (Click here).
Perform the active test of the leveling motors.
| Result | Proceed to |
| NG | A |
| OK (for LHD) | B |
| OK (for RHD) | C |
|
| ||||
|
| ||||
| A | ||
| ||