POWER WINDOW CONTROL SYSTEM > INITIALIZATION |
| INITIALIZE POWER WINDOW CONTROL SYSTEM (POWER WINDOW REGULATOR MOTOR ASSEMBLY (ALL DOORS)) |
Perform initialization according to the table below.
| Condition of Power Window | Proceed to |
| Initialization method when a power window regulator motor assembly has been replaced with a new one. | Procedure A |
Initialization method when a door window regulator assembly has been removed/installed or a door glass and/or door glass run etc. have been removed/installed or replaced with new ones.
| Procedure B |
| Initialization method when a reverse rotation malfunction occurs due to a sliding resistance change resulting from adjustment etc. | Procedure C |
Procedure A
Connect the auxiliary battery and turn the power switch on (IG) (at this time, the LED on the multiplex network master switch assembly, power window regulator switch assembly or rear power window regulator switch assembly blinks to indicate that it is ready for initialization).
Fully open the window by fully pushing down the multiplex network master switch assembly, power window regulator switch assembly or rear power window regulator switch assembly, and hold the switch for 1 second or more after the window is fully opened.
Fully close the power window by fully pulling up the multiplex network master switch assembly, power window regulator switch assembly or rear power window regulator switch assembly, and hold the switch for 1 second or more after the window is fully closed to reset the glass position. The LED on the multiplex network master switch assembly, power window regulator switch assembly or rear power window regulator switch assembly stops blinking and illuminates to indicate that initialization is complete.
Procedure B
Connect the auxiliary battery and turn the power switch on (IG).
Fully close the power window by fully pulling up the multiplex network master switch assembly, power window regulator switch assembly or rear power window regulator switch assembly, and hold the switch for 6 seconds or more after the window is fully closed (if the power window does not move or stops halfway even when the switch is fully pulled, release the switch and fully pull it again).
Fully open the window by pushing down the multiplex network master switch assembly, power window regulator switch assembly or rear power window regulator switch assembly, and hold the switch for 1 second or more after the window is fully opened.
Release the multiplex network master switch assembly, power window regulator switch assembly or rear power window regulator switch assembly. Then fully push down and hold the switch for 4 seconds or more.
Fully close the power window by fully pulling up the multiplex network master switch assembly, power window regulator switch assembly or rear power window regulator switch assembly, and hold the switch for 1 second or more after the window is fully closed to reset the glass position and complete initialization.
Procedure C
Connect the auxiliary battery and turn the power switch on (IG).
Fully open the window by fully pushing down the multiplex network master switch assembly, power window regulator switch assembly or rear power window regulator switch assembly, and hold the switch for 1 second or more after the window is fully opened.
Fully close the power window by fully pulling up the multiplex network master switch assembly, power window regulator switch assembly or rear power window regulator switch assembly, and hold the switch for 1 second or more after the window is fully closed to reset the glass position and complete initialization.