METER / GAUGE SYSTEM > Operating Light Control Rheostat does not Change Light Brightness |

| 1.SYSTEM CHECK |
Confirm the symptoms.
| Result | Proceed to |
| Meter illumination does not change in operating the light control rheostat. | A |
| Dimmer function cannot be canceled. | B |
|
| ||||
| A | |
| 2.READ VALUE USING INTELLIGENT TESTER (RHEOSTAT VALUE) |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Turn the intelligent tester on.
Enter the following menus: Body / Combination Meter / Data List.
Check the values by referring to the table below.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Rheostat value | Light control rheostat/Min.: 0 (dark), Max.: 255 (bright) | The light control rheostat value 0 (dark) | The value changes with the rheostat operation |
| The light control rheostat value 255 (bright) |
|
| ||||
| OK | |
| 3.READ VALUE USING INTELLIGENT TESTER (TAIL CANCEL SW) |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Turn the intelligent tester on.
Enter the following menus: Body / Combination Meter / Data List.
Check the values by referring to the table below.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Tail Cancel SW | Tail cancel switch/OFF or ON | OFF: Tail cancel switch off | - |
| ON: Tail cancel switch on | - |
|
| ||||
| OK | ||
| ||
| 4.INSPECT LIGHT CONTROL RHEOSTAT |
![]() |
Remove the light control rheostat (Click here).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| 1 (E) - 3 (RV) | Turn the light control rheostat knob fully downwards (MIN.) | Below 50 Ω |
| Light control rheostat knob position is between MIN. and MAX. | The value changes gradually (Between 0 to 12 kΩ) | |
| Turn the light control rheostat knob fully upwards (MAX.) | 8 to 12 kΩ |
| *a | Component without harness connected (Light Control Rheostat) |
|
| ||||
| OK | |
| 5.CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - LIGHT CONTROL RHEOSTAT) |
Disconnect the H19 and H40 connectors.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| H19-14 (REV) - H40-3 (RV) | Always | Below 1 Ω |
| H19-14 (REV) - Body ground | Always | 10 kΩ or higher |
| H19-36 (SW3) - H40-1 (E) | Always | Below 1 Ω |
| H19-36 (SW3) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||
| 6.READ VALUE USING INTELLIGENT TESTER (TAIL CANCEL SW) |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Turn the intelligent tester on.
Enter the following menus: Body / Combination Meter / Data List.
Check the values by referring to the table below.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Tail Cancel SW | Tail cancel switch/OFF or ON | OFF: Tail cancel switch off | - |
| ON: Tail cancel switch on | - |
|
| ||||
| OK | ||
| ||
| 7.INSPECT LIGHT CONTROL RHEOSTAT |
![]() |
Remove the light control rheostat (Click here).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| 5 (TC) - 7 (T) | Light control rheostat position is except below | Below 50 Ω |
| Turn the light control rheostat knob fully upwards (Tail cancel switch is on) | 8 to 12 kΩ |
| *a | Component without harness connected (Light Control Rheostat) |
|
| ||||
| OK | |
| 8.CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - LIGHT CONTROL RHEOSTAT) |
Disconnect the H19 and H40 connectors.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| H19-16 (SW1) - H40-7 (T) | Always | Below 1 Ω |
| H19-16 (SW1) - Body ground | Always | 10 kΩ or higher |
| H19-15 (TC) - H40-5 (TC) | Always | Below 1 Ω |
| H19-15 (TC) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||