HEATED OXYGEN SENSOR > INSPECTION

for Preparation Click here



1. INSPECT HEATED OXYGEN SENSOR


A219103E12
Text in Illustration 
*a
Component without harness connected
(Heated Oxygen Sensor)
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 (HT1B) - 2 (+B)
    20°C (68°F)
    11 to 16 Ω
    1 (HT1B) - 4 (E2)
    -
    10 kΩ or higher

    If the result is not as specified, replace the heated oxygen sensor.