HEATED OXYGEN SENSOR > INSPECTION |
| 1. INSPECT HEATED OXYGEN SENSOR |
![]() |
| *a | Component without harness connected (Heated Oxygen Sensor) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 (HT1B) - 2 (+B) | 20°C (68°F) | 11 to 16 Ω |
| 1 (HT1B) - 4 (E2) | - | 10 kΩ or higher |