INTEGRATION RELAY > INSPECTION

for Preparation Click here



1. INSPECT NO. 2 INTEGRATION RELAY



A216915E06


Text in Illustration 
*1
Integration Relay
-
-


  1. IG2 RELAY:



      A095606E12
    1. Measure the resistance according to the value(s) in the table below.
      Text in Illustration 
      *1
      Integration Relay

      Standard Resistance:

      Tester Connection
      Condition
      Specified Condition
      Integration relay (1C-1) - Integration relay (1A-4)
      Auxiliary battery voltage is not applied between terminals 1A-3 and 1A-2
      10 kΩ or higher
      Integration relay (1C-1) - Integration relay (1A-4)
      Auxiliary battery voltage is applied between terminals 1A-3 and 1A-2
      Below 1 Ω

      If the resistance is not as specified, replace the integration relay.



  1. BATT FAN RELAY:



      A095606E12
    1. Measure the resistance according to the value(s) in the table below.
      Text in Illustration 
      *1
      Integration Relay

      Standard Resistance:

      Tester Connection
      Condition
      Specified Condition
      Integration relay (1C-1) - Integration relay (1A-8)
      Auxiliary battery voltage is not applied between terminals 1A-7 and 1A-6
      10 kΩ or higher
      Integration relay (1C-1) - Integration relay (1A-8)
      Auxiliary battery voltage is applied between terminals 1A-7 and 1A-6
      Below 1 Ω

      If the resistance is not as specified, replace the integration relay.



  1. EFI MAIN RELAY:



      A095606E12
    1. Measure the resistance according to the value(s) in the table below.
      Text in Illustration 
      *1
      Integration Relay

      Standard Resistance:

      Tester Connection
      Condition
      Specified Condition
      Integration relay (1C-1) - Integration relay (1B-4)
      Auxiliary battery voltage is not applied between terminals 1B-2 and 1B-3
      10 kΩ or higher
      Integration relay (1C-1) - Integration relay (1B-4)
      Auxiliary battery voltage is applied between terminals 1B-2 and 1B-3
      Below 1 Ω

      If the resistance is not as specified, replace the integration relay.



  1. C/OPN RELAY:



      A095606E12
    1. Measure the resistance according to the value(s) in the table below.
      Text in Illustration 
      *1
      Integration Relay

      Standard Resistance:

      Tester Connection
      Condition
      Specified Condition
      Integration relay (1B-5) - Integration relay (1B-8)
      Auxiliary battery voltage is not applied between terminals 1B-6 and 1B-7
      10 kΩ or higher
      Integration relay (1B-5) - Integration relay (1B-8)
      Auxiliary battery voltage is applied between terminals 1B-6 and 1B-7
      Below 1 Ω

      If the resistance is not as specified, replace the integration relay.