INTEGRATION RELAY > INSPECTION |
| 1. INSPECT NO. 2 INTEGRATION RELAY |

| *1 | Integration Relay | - | - |
IG2 RELAY:
![]() |
Measure the resistance according to the value(s) in the table below.
| *1 | Integration Relay |
| Tester Connection | Condition | Specified Condition |
| Integration relay (1C-1) - Integration relay (1A-4) | Auxiliary battery voltage is not applied between terminals 1A-3 and 1A-2 | 10 kΩ or higher |
| Integration relay (1C-1) - Integration relay (1A-4) | Auxiliary battery voltage is applied between terminals 1A-3 and 1A-2 | Below 1 Ω |
BATT FAN RELAY:
![]() |
Measure the resistance according to the value(s) in the table below.
| *1 | Integration Relay |
| Tester Connection | Condition | Specified Condition |
| Integration relay (1C-1) - Integration relay (1A-8) | Auxiliary battery voltage is not applied between terminals 1A-7 and 1A-6 | 10 kΩ or higher |
| Integration relay (1C-1) - Integration relay (1A-8) | Auxiliary battery voltage is applied between terminals 1A-7 and 1A-6 | Below 1 Ω |
EFI MAIN RELAY:
![]() |
Measure the resistance according to the value(s) in the table below.
| *1 | Integration Relay |
| Tester Connection | Condition | Specified Condition |
| Integration relay (1C-1) - Integration relay (1B-4) | Auxiliary battery voltage is not applied between terminals 1B-2 and 1B-3 | 10 kΩ or higher |
| Integration relay (1C-1) - Integration relay (1B-4) | Auxiliary battery voltage is applied between terminals 1B-2 and 1B-3 | Below 1 Ω |
C/OPN RELAY:
![]() |
Measure the resistance according to the value(s) in the table below.
| *1 | Integration Relay |
| Tester Connection | Condition | Specified Condition |
| Integration relay (1B-5) - Integration relay (1B-8) | Auxiliary battery voltage is not applied between terminals 1B-6 and 1B-7 | 10 kΩ or higher |
| Integration relay (1B-5) - Integration relay (1B-8) | Auxiliary battery voltage is applied between terminals 1B-6 and 1B-7 | Below 1 Ω |