AIR CONDITIONING SYSTEM > DATA LIST / ACTIVE TEST

for Preparation Click here



DATA LIST

HINT:
Using the intelligent tester to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.

NOTICE:
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.

  1. Turn the power switch off.

  2. Connect the intelligent tester to the DLC3.

  3. Turn the power switch on (IG).

  4. Turn the intelligent tester on.

  5. Enter the following menus: Body / Air Conditioner / Data List.

  6. Check the value(s) by referring to the table below.

    Air Conditioner 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Room Temperature Sensor
    Room temperature sensor /
    Min.: -6.5°C (20.3°F)
    Max.: 57.25°C (135.05°F)
    Actual cabin temperature displayed
    -
    Ambient Temp Sensor
    Ambient temperature sensor /
    Min.: -23.3°C (-9.94°F)
    Max.: 65.95°C (150.71°F)
    Actual ambient temperature displayed
    -
    Adjusted Ambient Temp
    Adjusted ambient temperature /
    Min.: -30.8°C (-23.44°F)
    Max.: 50.8°C (123.44°F)
    -
    -
    Evaporator Fin Thermistor
    Evaporator temperature sensor /
    Min.: -29.7°C (-21.46°F)
    Max.: 59.55°C (139.19°F)
    Actual evaporator temperature displayed
    -
    Evaporator Target Temp
    Evaporator target temperature /
    Min.: -327.68°C (-557.82°F)
    Max.: 327.67°C (621.81°F)
    Evaporator target temperature displayed
    -
    Solar Sensor (D side)
    Driver side solar sensor /
    Min.: 0
    Max.: 255
    Driver side solar sensor value increases as brightness increases
    -
    Solar Sensor (P side)
    Front passenger side solar sensor /
    Min.: 0
    Max.: 255
    Front passenger side solar sensor value increases as brightness increases
    -
    Engine Coolant Temp
    Engine coolant temperature sensor /
    Min.: 1.3°C (34.34°F)
    Max.: 90.55°C (194.99°F)
    Actual engine coolant temperature displayed
    -
    Set Temperature (D side)
    Driver side set temperature /
    Min.: 17.5°C (63.5°F)
    Max.: 32.5°C (90.5°F)
    Driver side actual set temperature displayed
    -
    Set Temperature (P side)
    Front passenger side set temperature /
    Min.: 17.5°C (63.5°F)
    Max.: 32.5°C (90.5°F)
    Front passenger side actual set temperature displayed
    -
    Blower Motor Speed Level
    Blower motor speed level /
    Min.: 0
    Max.: 31
    Displayed speed level increases in range between 0 and 31 as blower motor speed increases
    -
    Regulator Pressure Sensor
    Air conditioning pressure sensor /
    Min.: -0.45668 MPaG
    Max.: 3.29437 MPaG
    Actual regulator pressure displayed
    -
    Air Mix Servo Targ Pulse (D)
    Driver side air mix servo motor target pulse /
    Min.: 0
    Max.: 255
    for LHD:
    MAX. COLD: 92 (pulse)
    MAX. HOT: 5 (pulse)
    for RHD:
    MAX. COLD: 6 (pulse)
    MAX. HOT: 93 (pulse)
    -
    Air Mix Servo Actual Pulse (D)
    Driver side air mix servo motor actual pulse /
    Min.: 0
    Max.: 255
    for LHD:
    MAX. COLD: 92 (pulse)
    MAX. HOT: 5 (pulse)
    for RHD:
    MAX. COLD: 6 (pulse)
    MAX. HOT: 93 (pulse)
    -
    Air Mix Servo Targ Pulse (P)
    Front passenger side air mix servo motor target pulse /
    Min.: 0
    Max.: 255
    for LHD:
    MAX. COLD: 6 (pulse)
    MAX. HOT: 93 (pulse)
    for RHD:
    MAX. COLD: 92 (pulse)
    MAX. HOT: 5 (pulse)
    -
    Air Mix Servo Actual Pulse (P)
    Front passenger side air mix servo motor actual pulse /
    Min.: 0
    Max.: 255
    for LHD:
    MAX. COLD: 6 (pulse)
    MAX. HOT: 93 (pulse)
    for RHD:
    MAX. COLD: 92 (pulse)
    MAX. HOT: 5 (pulse)
    -
    Air Outlet Servo Pulse (D)
    Air outlet servo motor target pulse /
    Min.: 0
    Max.: 255
    FACE: 47 (pulse)
    B/L: 37 (pulse)
    FOOT: 18 or 23 (pulse)
    FOOT/DEF: 9 (pulse)
    DEF: 5 (pulse)
    -
    Air Outlet Servo Actu Pulse (D)
    Air outlet servo motor actual pulse /
    Min.: 0
    Max.: 255
    FACE: 47 (pulse)
    B/L: 37 (pulse)
    FOOT: 18 or 23 (pulse)
    FOOT/DEF: 9 (pulse)
    DEF: 5 (pulse)
    -
    Air Inlet Damper Targ Pulse
    Air inlet servo motor target pulse /
    Min.: 0
    Max.: 255
    for LHD:
    RECIRCULATION: 19 (pulse)
    FRESH: 7 (pulse)
    for RHD:
    RECIRCULATION: 25 (pulse)
    FRESH: 7 (pulse)
    -
    Air Inlet Damper Actual Pulse
    Air inlet servo motor actual pulse /
    Min.: 0
    Max.: 255
    for LHD:
    RECIRCULATION: 19 (pulse)
    FRESH: 7 (pulse)
    for RHD:
    RECIRCULATION: 25 (pulse)
    FRESH: 7 (pulse)
    -
    Electric Heater Active Level*2
    Heater active level /
    Min.: 0
    Max.: 3
    Actual electric heater active level displayed
    -
    Compressor Speed
    Compressor speed /
    Min.: 0 rpm
    Max.: 65535 rpm
    Actual rotation speed in the range between 0 rpm and 7500 rpm displayed
    -
    Compressor Target Speed
    Compressor target speed /
    Min.: 0 rpm
    Max.: 65535 rpm
    Actual rotation speed in the range between 0 rpm and 7500 rpm displayed
    -
    ECO Switch
    ECO switch /
    OFF or ON
    ECO switch operated: ON
    (when knob is held in ECO position)
    -
    ECO switch not operated: OFF
    (when knob is not held in ECO position)
    -
    Pls Servo Test Sts
    Pulse servo motor test status /
    Move, Comp, Error, Stop
    Move: Servo motor now testing
    Comp: Servo motor test completed normally
    Error: Servo motor test completed abnormally
    Stop: Servo motor test interrupted
    -
    Compressor Drive Check
    Compressor drive check /
    OK or NG
    NG: Compressor does not drive
    OK: Compressor drives
    -
    Glass Temperature*1
    Glass temperature /
    Min.: -327.68°C (-557.82°F)
    Max.: 327.67°C (621.81°F)
    Actual glass temperature displayed
    -
    Glass Surroundings Temperature*1
    Glass surroundings temperature /
    Min.: -327.68°C (-557.82°F)
    Max.: 327.67°C (621.81°F)
    Actual glass surroundings temperature displayed
    -
    Glass Humidity*1
    Glass humidity /
    Min.: 0 (%)
    Max.: 200 (%)
    Actual glass humidity displayed
    -
    Number of Trouble Codes
    Number of trouble codes /
    Min.: 0
    Max.: 255
    Number of DTCs displayed
    -

    1. *1: w/ Air Conditioning Thermistor Assembly
    2. *2: w/ PTC Heater Assembly


ACTIVE TEST

HINT:
Using the intelligent tester to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.

  1. Turn the power switch off.

  2. Connect the intelligent tester to the DLC3.

  3. Turn the power switch on (IG).

  4. Turn the intelligent tester on.

  5. Enter the following menus:

    1. for Air Conditioner: Body / Air Conditioner / Active Test.

    2. for Engine and ECT: Powertrain / Engine and ECT / Active Test.

  6. Check the operation by referring to the table below.

    Air Conditioner 
    Tester Display
    Test Part
    Control Range
    Diagnostic Note
    Blower Motor
    Blower motor
    Min.: 0, Max.: 31
    -
    Compressor Target Speed
    Compressor target speed
    Min.: 0, Max.: 7500
    -
    Defogger Relay (Rear)
    Defogger relay (Rear)
    OFF, ON
    -
    Deicer Relay (Front)
    Deicer relay (Front)
    OFF, ON
    -
    Heater Active Level*1
    PTC heater assembly
    Min.: 0, Max.: 3
    -
    Air Mix Servo Targ Pulse (D)
    Air mix servo motor pulse (for driver side)
    Min.: 0, Max.: 255
    -
    Air Mix Servo Targ Pulse (P)
    Air mix servo motor pulse (for front passenger side)
    Min.: 0, Max.: 255
    -
    Air Outlet Servo Pulse (D)
    Air outlet servo motor pulse
    Min.: 0, Max.: 255
    -
    Air Inlet Damper Targ Pulse
    Air inlet damper target pulse
    Min.: 0, Max.: 255
    -
    *1: w/ PTC Heater Assembly

    Engine and ETC 
    Tester Display
    Test Part
    Control Range
    Diagnostic Note
    Control the Electric Cooling Fan
    Electric Cooling Fan
    OFF, ON
    -