ELECTRONIC SHIFT LEVER SYSTEM > FREEZE FRAME DATA |
| CHECK FREEZE FRAME DATA |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Turn the intelligent tester on.
Enter the following menus: Chassis / Transmission Control / DTC.
Select a DTC in order to display its freeze frame data.
| LIST OF FREEZE FRAME DATA |
| Tester Display | Measurement Item | Reference Value |
| Shift Pos Display (P) | Shift position display (P) | ON / OFF |
| Shift Pos Display (Not P) | Shift position display (not P) | ON / OFF |
| Master Caution Display | Master caution display | Disp / Nondisp |
| PSW Indicator Mode | PSW indicator mode | OFF / ON |
| U Phase Voltage Value | U phase voltage value | 0 to 39 V |
| V Phase Voltage Value | V phase voltage value | 0 to 39 V |
| W Phase Voltage Value | W phase voltage value | 0 to 39 V |
| Battery Voltage Value | BATT voltage value | 0 to 19 V |
| IG(+B) Voltage Value | IG (+B) voltage value | 0 to 19 V |
| Cmplte of Learn Lck Pos | Completion of lock position learning | OK / NG |
| Cmplte of Learn Unlck Pos | Completion of unlock position learning | OK / NG |
| # of Trip Cuntr after Learn | Counter for number of trip after learning | 0 to 65535 |
| Main Relay for Motor Drive | P CON MTR relay (transaxle parking lock control relay) for motor drive | ON / OFF |
| U Phase Crnt-Carry Status | U phase current-carrying status | ON / OFF |
| V Phase Crnt-Carry Status | V phase current-carrying status | ON / OFF |
| W Phase Crnt-Carry Status | W phase current-carrying status | ON / OFF |
| U Phase Voltage Status | U phase voltage status | ON / OFF |
| V Phase Voltage Status | V phase voltage status | ON / OFF |
| W Phase Voltage Status | W phase voltage status | ON / OFF |
| Battery Voltage Status | BATT voltage status | ON / OFF |
| IG(+B) Phase Vol Status | IG (+B) phase voltage status | ON / OFF |
| ACC Condition Signal | ACC condition signal | ON / OFF |
| Init Drv Cntrl Completed | Initial drive control completed | OK / NG |
| Cmplte of Detct Lck Pos | Completion of detecting lock position | OK / NG |
| Cmplte of Detct Unlck Pos | Completion of detecting unlock position | OK / NG |
| P/Not P Move Shft Range | P/Not P movable shift range | Set / Unset |
| Main Relay | P CON MTR relay (transaxle parking lock control relay) | Normal / Abnoml |
| Current flag record | Current flag record | ON / OFF |
| Fail Rank | Fail rank | 0 to 255 |
| Detail Information # | - | - |