DTC C2303 Short in Power Source Relay Circuit |
| DTC No. | DTC Detection Condition | Trouble Area |
| C2303 | When the P CON MTR relay (transaxle parking lock control relay) is off, voltage of transmission control ECU assembly terminal MUA, MVA and MWA are 6 V or more for 0.064 seconds or more. |
|
| 1.CHECK SHIFT CONTROL ACTUATOR ASSEMBLY (SHIFT CONTROL ACTUATOR ASSEMBLY POWER SOURCE CIRCUIT) |
Disconnect connector D2 from the shift control actuator assembly.
![]() |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| D2-2 (BMA) - Body ground | Power switch off | Below 1 V |
| *a | Front view of wire harness connector (to Shift Control Actuator Assembly) |
Connect the shift control actuator assembly connector.
|
| ||||
| OK | |
| 2.CHECK HARNESS AND CONNECTOR (TRANSMISSION CONTROL ECU ASSEMBLY - SHIFT CONTROL ACTUATOR) |
Disconnect connector A21 from the transmission control ECU assembly.
Disconnect connector D2 from the shift control actuator assembly.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A21-5 (MUA) or D2-1 (MUA) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| A21-2 (MVA) or D2-6 (MVA) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| A21-1 (MWA) or D2-7 (MWA) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| *a | Front view of wire harness connector (to Transmission Control ECU Assembly) |
| *b | Front view of wire harness connector (to Shift Control Actuator Assembly) |
Connect the shift control actuator assembly connector.
Connect the transmission control ECU assembly connector.
|
| ||||
| OK | ||
| ||
| 3.INSPECT P CON MTR RELAY (TRANSAXLE PARKING LOCK CONTROL RELAY) |
![]() |
Remove the P CON MTR relay (transaxle parking lock control relay) from the engine room junction block assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 3 - 5 | Auxiliary battery voltage is not applied between terminals 1 and 2 | 10 kΩ or higher |
| Auxiliary battery voltage is applied between terminals 1 and 2 | Below 1 Ω |
Reinstall the P CON MTR relay (transaxle parking lock control relay).
|
| ||||
| OK | |
| 4.CHECK HARNESS AND CONNECTOR (TRANSMISSION CONTROL ECU ASSEMBLY - P CON MTR RELAY) |
Disconnect connector A21 from the transmission control ECU assembly.
Remove the P CON MTR relay (transaxle parking lock control relay) from the engine room junction block assembly.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A21-23 (BMA) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| *a | Front view of wire harness connector (to Transmission Control ECU Assembly) |
Reinstall the P CON MTR relay (transaxle parking lock control relay).
Connect the transmission control ECU assembly connector.
|
| ||||
| OK | |
| 5.CHECK HARNESS AND CONNECTOR (SHIFT CONTROL ACTUATOR ASSEMBLY - P CON MTR RELAY) |
Disconnect connector D2 from the shift control actuator assembly.
Remove the P CON MTR relay (transaxle parking lock control relay) from the engine room junction block assembly.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| D2-2 (BMA) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| *a | Front view of wire harness connector (to Shift Control Actuator Assembly) |
Reinstall the P CON MTR relay (transaxle parking lock control relay).
Connect the shift control actuator assembly connector.
|
| ||||
| OK | ||
| ||