RELAY > ON-VEHICLE INSPECTION

for Preparation Click here



1. INSPECT DIM RELAY


    E222293E01
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    3 - 5
    Voltage is not applied between terminals 1 and 2
    10 kΩ or higher
    3 - 5
    Voltage is applied between terminals 1 and 2
    Below 1 Ω
    3 - 4
    Voltage is not applied between terminals 1 and 2
    Below 1 Ω
    3 - 4
    Voltage is applied between terminals 1 and 2
    10 kΩ or higher

    If the result is not as specified, replace the DIM relay.



2. INSPECT DRL RELAY


    E222294E02
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    3 - 5
    Voltage is not applied between terminals 1 and 2
    10 kΩ or higher
    3 - 5
    Voltage is applied between terminals 1 and 2
    Below 1 Ω

    If the result is not as specified, replace the DRL relay.



3. INSPECT RR FOG RELAY


    E222294E02
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    3 - 5
    Voltage is not applied between terminals 1 and 2
    10 kΩ or higher
    3 - 5
    Voltage is applied between terminals 1 and 2
    Below 1 Ω

    If the result is not as specified, replace the RR FOG relay.