HAZARD WARNING SWITCH > INSPECTION

for Preparation Click here



1. INSPECT HAZARD WARNING SIGNAL SWITCH ASSEMBLY


    E212429E01
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    6 (HAZ) - 3 (GND)
    Hazard warning switch off
    10 kΩ or higher
    Hazard warning switch on
    Below 1 Ω

    Text in Illustration 
    *a
    Component without harness connected
    (Hazard Warning Signal Switch Assembly)
    If the result is not as specified, replace the hazard warning signal switch assembly.