POWER WINDOW CONTROL SYSTEM > Auto Up Operation does not Fully Close Power Window (Jam Protection Function is Activated) |
| 1.PERFORM INITIALIZATION (APPLICABLE LOCATION) |
Initialize the power window regulator motor assembly (applicable location) (Click here).
| NEXT | |
| 2.CHECK POWER WINDOW CONTROL SYSTEM (AUTO UP/DOWN FUNCTION (APPLICABLE LOCATION)) |
Check that all power windows move when the auto up and down functions of the multiplex network master switch assembly and power window regulator switch assemblies (for rear LH and rear RH sides) are operated (Click here).
|
| ||||
| OK | ||
| ||
| 3.CHECK WINDOW GLASS SLIDING MOVEMENT (APPLICABLE LOCATION) |
Remove the window regulator.
Install the window glass onto the door glass run.
Check if the door window regulator operates smoothly.
Check that the window glass slides smoothly when sliding it up by hand.
| Result | Proceed to |
| NG | A |
| OK (Driver door power window) | B |
| OK (Front passenger side power window) | B |
| OK (Rear LH side power window) | C |
| OK (Rear RH side power window) | C |
|
| ||||
|
| ||||
| A | ||
| ||