DTC P0AFC-150 Hybrid Battery Pack Sensor Module |
| DTC NO. | INF Code | DTC Detection Condition | Trouble Area |
| P0AFC | 150 | Power source voltage of the battery smart unit drops during precharge. |
|

| 1.CHECK HARNESS AND CONNECTOR (IGCT VOLTAGE) |
Check that the service plug grip is not installed.
Turn the power switch on (IG).
![]() |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| i1-4 (IGCT) - i1-8 (GND) | Power switch on (IG) | 11 to 14 V |
| *a | Component with harness connected (Battery Smart Unit) |
Turn the power switch off.
|
| ||||
| OK | ||
| ||
| 2.CHECK HARNESS AND CONNECTOR (GND - BODY GROUND) |
Check that the service plug grip is not installed.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| i1-8 (GND) - Body ground | Power switch off | Below 1 Ω |
| *a | Rear view of wire harness connector (to Battery Smart Unit) |
|
| ||||
| OK | ||
| ||