SOLAR SENSOR > INSPECTION

for Preparation Click here



1. INSPECT AUTOMATIC LIGHT CONTROL SENSOR (for LHD)


    E152686E76
  1. Disconnect the automatic light control sensor (solar sensor) connector.

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Condition
    Specified Condition
    6 (CLTB) - 3 (CLTE)
    Power switch off
    Below 1 V
    6 (CLTB) - 3 (CLTE)
    Power switch on (IG)
    11 to 14 V

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to Automatic Light Control Sensor (Solar Sensor))
    If the voltage is not as specified, repair or replace the wire harness or connector.



    E161710E74
  1. Reconnect the automatic light control sensor (solar sensor) connector.

  1. Turn the power switch on (IG).

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Condition
    Specified Condition
    1 (TSL) - 3 (CLTE)*1
    Sensor is exposed to electric light
    0.8 to 4.3 V
    1 (TSL) - 3 (CLTE)*1
    Sensor is covered with a cloth
    Below 0.8 V
    2 (TSR) - 3 (CLTE)*2
    Sensor is exposed to electric light
    0.8 to 4.3 V
    2 (TSR) - 3 (CLTE)*2
    Sensor is covered with a cloth
    Below 0.8 V

    Text in Illustration 
    *A
    for Driver Side
    *B
    for Front Passenger Side
    *a
    Component with harness connected
    (Automatic Light Control Sensor (Solar Sensor))

    NOTICE:
    1. The connection procedure for using a digital tester such as a TOYOTA electrical tester is shown above. When using an analog tester, connect the positive (+) lead to terminal 3 and the negative (-) lead to terminal 1*1 (2*2) of the automatic light control sensor (solar sensor).
    2. While using the battery during inspection, do not bring the positive and negative tester probes too close to each other as a short circuit may occur.

    1. *1: for Driver Side
    2. *2: for Front Passenger Side

    HINT:
    1. Use an incandescent light for inspection. Bring it within about 30 cm (11.8 in.) of the solar sensor.
    2. As the inspection light is moved away from the sensor, the voltage decreases.

    If the voltage is not as specified, replace the automatic light control sensor (solar sensor).



2. INSPECT AUTOMATIC LIGHT CONTROL SENSOR (for RHD)


    E152686E76
  1. Disconnect the automatic light control sensor (solar sensor) connector.

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Condition
    Specified Condition
    6 (CLTB) - 3 (CLTE)
    Power switch off
    Below 1 V
    6 (CLTB) - 3 (CLTE)
    Power switch on (IG)
    11 to 14 V

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to Automatic Light Control Sensor (Solar Sensor))
    If the voltage is not as specified, repair or replace the wire harness or connector.



    E161710E76
  1. Reconnect the automatic light control sensor (solar sensor) connector.

  1. Turn the power switch on (IG).

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Condition
    Specified Condition
    1 (TSL) - 3 (CLTE)*2
    Sensor is exposed to electric light
    0.8 to 4.3 V
    1 (TSL) - 3 (CLTE)*2
    Sensor is covered with a cloth
    Below 0.8 V
    2 (TSR) - 3 (CLTE)*1
    Sensor is exposed to electric light
    0.8 to 4.3 V
    2 (TSR) - 3 (CLTE)*1
    Sensor is covered with a cloth
    Below 0.8 V

    1. *1: for Driver Side
    2. *2: for Front Passenger Side
    Text in Illustration 
    *A
    for Driver Side
    *B
    for Front Passenger Side
    *a
    Component with harness connected
    (Automatic Light Control Sensor (Solar Sensor))

    NOTICE:
    1. The connection procedure for using a digital tester such as a TOYOTA electrical tester is shown above. When using an analog tester, connect the positive (+) lead to terminal 3 and the negative (-) lead to terminal 1*2 (2*1) of the automatic light control sensor (solar sensor).
    2. While using the battery during inspection, do not bring the positive and negative tester probes too close to each other as a short circuit may occur.

    HINT:
    1. Use an incandescent light for inspection. Bring it within about 30 cm (11.8 in.) of the solar sensor.
    2. As the inspection light is moved away from the sensor, the voltage decreases.

    If the voltage is not as specified, replace the automatic light control sensor (solar sensor).